Get a Quote
Water Treatment System

RO Water Treatment System

Pressure-driven membrane separation for beverage plants. When system pressure exceeds the osmotic pressure of the feed water, water molecules pass through the membrane while ions, organic matter, bacteria and viruses are retained and flushed to drain. Configured from your raw-water analysis rather than sold as a fixed model.
  • ApplicationBottled purified water, beverage process water, CIP water
  • CapacityProject-configurable — sized to filler consumption plus headroom
  • Membrane stagesSingle pass or double pass
  • Contact materialSUS304 or SUS316 by project specification
  • ControlManual, semi-automatic or PLC with touchscreen
  • Warranty12 months
Manufacturing since 2005 Exported to 30+ countries Factory acceptance testing Installation & training support

Reverse Osmosis System

Reverse Osmosis(RO) is membrane-technology filtration method that removes many types of large molecules and ions from solutions by applying pressure to the solution when it is on one side of a selective membrane. 

Reverse osmosis is most common known for its use in drinking water purification from seawater, removing the salt and other substances from the water molecules. It is widely used in producing ultra-pure water, pharmaceutics process water, cosmetics, seawater desalination, brackish water desalination, drinking purified water, sitilled water, high pressure boiler water, power station water supply .

Typical Reverse Osmosis Processing Flow:

Raw water pump → Silica sand filter → Activated carbon filter→ Sodium ion exchanger → Security filter → High-pressure pump →Reverse osmosis system →Uv sterilizer→Ozone sterilizer →Finished Water tank
1. Raw Water Pump: provide the pressure to silica sandfilter/active carbon filter
2. Silica Sand Filter: get rid of turbidity, suspended matter, organic matter, colloid and so on
3. Activated Carbon Filter: Remove the color, free chloride, organic matter, harmful matter and so on
4, Water Softener: Get rid of calcium and magnesium ions in original / source water, reduce water hardness.
5. Security Filter: prevent any deposition of large Particles into the RO membrane, The accuracy is 5um, for holding back any large particulates such as large iron, dust, suspended matter, impurity.
6. High Pressure Pump: Provide the high pressure to RO membrane(at least 2.0 Mpa).
7. RO system: main part of pure water treatment plant. The desaltation rate upto 99%, it is capable of removing over 99% of ions and 98% of organic.
8.UV Sterilizer : kill some bad substance that may also pass through the reverse osmosis
9.Ozone Sterilizer: Use ozone Kill bacteria not killed by UV
10.Finished Water Tank : For filter water storage

Pure Water Treatment System With Reverse Osmosis Technology
Capacity
Capacity (Ton Per hour)
General power
Size (L*W*H)
Weight (kg)
RO-250L/H
0.25ton
0.55kw
1350*900*1620mm
250kg
RO-500L/H
0.5ton
0.75kw
1550*900*1820mm
350kg
RO-1000L/H
1ton
1.5kw
1980*900*1940mm
500kg
RO-2000L/H
2ton
2kw
4800*700*2050mm
700kg
RO-3000L/H
3ton
5kw
6000*800*2200mm
800kg
RO-4000L/H
4ton
6.5kw
7000*900*2400mm
1000kg
RO-5000L/H
5ton
8kw
8000*1000*2700mm
1500kg
RO-6000L/H
6ton
12kw
8500*1600*1920mm
2000kg
RO-8000L/H
8ton
15kw
1000*1870*3000mm
4000kg
RO-10000L/H
10ton
20kw
12000*1700*3500mm
4500kg
RO-15000L/H
15ton
25kw
12500*1700*3500mm
6500kg
RO-20000L/H
20ton
30kw
13000*1900*3500mm
9000kg
RO-30000L/H
30ton
35kw
13500*2300*3800mm
12000kg

 

Technical Specifications

All technical data is for reference only. Final specifications will be confirmed in technical agreement after reviewing your raw water report and requirements.
Example design point shown for reference. Capacity is configured per project.
Product typeIndustrial reverse osmosis water treatment system
Nominal capacityProject-configurable · example design point 2,000 L/hour
Source waterTap water, well water or other source, subject to laboratory analysis
Main processPretreatment → precision filtration → reverse osmosis → terminal disinfection
Membrane stagesSingle pass or double pass, according to required treated-water quality
Contact materialSUS304 or SUS316, according to water chemistry and process standard
Control systemManual, semi-automatic or PLC control with operator interface

Configuration Options

These decisions define the machine you receive. Each is confirmed before manufacturing starts.
Water-report-based sizing

Membrane area, pump pressure and recovery rate are calculated from your laboratory analysis, target output and required treated-water quality.

Single or double pass

Single pass suits most bottled water. Double pass is specified where conductivity targets are stricter or where the source has high dissolved solids.

Scope of Supply

What is included as standard. Items outside this list are quoted separately and stated in the technical agreement.
  • ✓RO skid with membrane housings and membranes
  • ✓High-pressure pump and motor
  • ✓Precision cartridge filter ahead of the membranes
  • ✓Control cabinet built to destination electrical standard

Pretreatment filters, storage tanks, disinfection units and distribution pipework are supplied as part of the complete treatment train. See the water treatment category for the full equipment list.

Site Requirements

Confirm these before delivery so installation is not delayed on arrival.
  • Floor spaceLevel concrete area with clearance around the skid for membrane replacement
  • Power supplyVoltage, frequency, phases and available capacity confirmed in advance

Frequently Asked Questions

What information is needed to size an industrial RO system?

A recent raw-water analysis, the treated-water quality you need to reach, hourly capacity, daily operating hours, target recovery rate, destination country and the utilities available on site.

Can the RO system be integrated with a beverage filling line?

Yes. The system is engineered with treated-water storage, distribution, disinfection and controls for connection to beverage processing or filling equipment. Capacity is normally sized above nominal filler consumption to allow for CIP and peak demand.

What is RO system used for?

RO (Reverse Osmosis) system removes suspended solids, heavy metals, bacteria, salts and impurities from raw water, to produce purified water for PET bottled water filling line.

What raw water sources can RO system handle?

It can treat tap water, well water, river water and underground water. The design is based on raw water quality report, especially TDS value.

What is the TDS range of RO treated water?

Normally, raw water TDS can be reduced by 95%~98%. - If raw water TDS <1000ppm, treated water TDS can reach ≤10–50 ppm, which meets drinking purified water standard.

What pre-treatment units are equipped before RO membrane?

Standard pre-treatment: raw water tank → raw water pump → quartz sand filter → activated carbon filter → softener (ion exchange) → security filter (5μm).

What material for RO vessel and pipeline?

RO pressure vessel: FRP; water pipeline: UPVC or SUS304 stainless steel.

What brand RO membrane do you use?

We can supply DOW, Vontron, Hydranautics according to client request.

How long is the service life of RO membrane?

Under proper operation & regular maintenance, RO membrane service life is 2–3 years.

What is the recovery rate of RO system?

Single stage RO recovery rate: 50%~75%. Two stage RO can achieve higher recovery rate.

Is CIP cleaning system included?

CIP chemical cleaning device is optional. It is recommended for long term operation to clean fouling on RO membranes.

What power supply for RO water treatment system?

Standard: 380V / 3Ph / 50Hz. Custom voltage available as per local requirement.

What maintenance work is needed routinely?

1. Replace security filter cartridge periodically. 2. Regenerate water softener resin. 3. Monitor TDS and pressure. 4. Perform CIP cleaning when pressure difference rises

Can RO system work automatically?

Yes, automatic version with PLC + touch screen, auto start/stop, low pressure & high pressure protection. Manual control version is also available for small capacity.

What is warranty period?

12 months warranty from shipment date (consumables like filter cartridge, RO membrane excluded). Lifetime technical support.

What certificates can you provide?

12 months warranty from shipment date (consumables like filter cartridge, RO membrane excluded). Lifetime technical support.

Enquiry

Send Your Requirements

The more of these we have up front, the more accurate the first quotation will be.
  • Raw-water analysis — laboratory report, if available
  • Water source — municipal, borehole, spring or surface
  • Treated-water quality you need to reach —
  • Hourly capacity, daily operating hours —
  • Target recovery rate, destination country and the utilities available on site —

WhatsApp +86 136 9173 6867 · +86 138 2520 5960

Industrial RO System Enquiry

No file chosen
YouTube